Figure 6

Western blot of SERT. (A) The anti-SERT antibody detected a major band at approximately 67 kDa. (B) Normalisation of the bands to the total protein load of the Coomassie-labelled membrane showed that there was no significant difference in the SERT content between the ileum and colon tissue (n = 5).