Table 4 Gravimetric parameters for Copper in 1.0 M HCl solution with and without AFM extract (250 mg L–1) at various temperatures.
Temperature (K) | AFM extract | CR (μg cm–2 h–1) | ηW (%) |
|---|---|---|---|
298 | 0 | 54.9 | – |
+ | 4.9 | 91.0 | |
313 | 0 | 57.3 | – |
+ | 6.1 | 89.3 | |
323 | 0 | 63.8 | – |
+ | 11.3 | 82.2 | |
333 | 0 | 75.2 | – |
+ | 15.8 | 78.9 |