Table 7 Cracking time and range of electric current for each concrete mix.

From: A study of chloride binding capacity of concrete containing supplementary cementitious materials

Mix no

Cracking time (day)

Range of electric current (milli-ampere)

1

OPC-0.4%

6

7–18

2

OPC-0.8%

6

4–26

3

15%FA-0.4%

47

210

4

15%FA-0.8%

42

310

5

35%FA-0.4%

15

1–16

6

35%FA-0.8%

15

1–16

7

15%GGBFS-0.4%

4

10–22

8

15%GGBFS-0.8%

6

10–22

9

35%GGBFS-0.4%

42

513

10

35%GGBFS-0.8%

29

116

11

5%MK-0.4%

8

4–27

12

5%MK-0.8%

7

7–26

13

10%MK-0.4%

5

7–18

14

10%MK-0.8%

5

9–18

15

15%MK-0.4%

7

6–18

16

15%MK-0.8%

7

6–20

17

35%MK-0.4%

No cracking observed

210.5

18

35%MK-0.8%

211

  1. Significant values are in [bold].