Table 1 The designed values of the converter.

From: Enhanced control strategy for photovoltaic emulator operating in continuously changing environmental conditions based on shift methodology

Parameter

Value

Input voltage, Vi

48 V

Switching frequency, fs

31 kHz

Duty cycle, D

0.05–0.9

Internal resistance of L, rL

0.631 Ω

Internal resistance of C, rC

0.134 Ω

PVE inductance, Lpve

3.52 mH

PVE Capacitance, Cpve

80 uF