Table 6 Optimal incorporation of single and multiple PV and WT units integrated into 69-bus under residential load type using mPDO algorithm.

From: Boosting prairie dog optimizer for optimal planning of multiple wind turbine and photovoltaic distributed generators in distribution networks considering different dynamic load models

 

Bus/size/OPF

Capacity

Total PV

Total energy

PL

Energy loss

PLMI

kW

kWh

kW

kWh

%

kWh

%

Without DG

1868.0756

1-PV

61/1489.0365/1

11,207.1613

1489.0365

11,207.1613

23.0738

1389.4353

25.6221

2-PVs

17/419.2299/1

3155.3135

1836.7008

13,823.8395

28.4611

1349.2406

27.7738

61/1417.4709/1

10,668.526

     

3-PVs

11/405.9945/1

3055.6983

2077.9086

15,639.2792

32.1988

1341.6839

28.1783

17/302.9161/1

2279.8836

     

61/1368.998/1

10,303.6973

     

1-WT

61/1316.8861/0.8164

12,441.3026

12,441.3026

25.6147

1313.3289

29.6962

2-WTs

17/365.5528/0.8290

3453.5655

15,292.6953

31.4853

1268.3281

32.1051

61/1253.1474/0.8156

11,839.1298

     

3-WTs

11/338.2781/0.81515

3195.8881

17,179.1904

35.3693

1260.2829

32.5358

17/268.2247/0.8339

2534.0573

     

61/1211.8789/0.8156

11,449.245