Table 9 Simultaneous integration of multiple PV and WT units into 69-bus DN using the mPDO algorithm under uncertainty for different load type.
DG allocation | Unit capacity | Total capacity | Total energy | PL | Energy loss | PLMI | |||
|---|---|---|---|---|---|---|---|---|---|
Bus | Capacity | OPF | kWh | kW | kWh | % | kWh | % | |
Commercial type | 12 | 592.1657 | 1 | 4456.9068 | 1566.6621 | 11,791.4062 | 67.9059 | 395.9191 | 81.7884 |
60 | 472.8394 | 1 | 3558.8030 | ||||||
64 | 501.6569 | 1 | 3775.6964 | ||||||
17 | 396.6760 | 0.7000 | 3747.6024 | - | 24,438.7642 | ||||
49 | 884.2427 | 0.8125 | 8353.8972 | ||||||
61 | 1305.8739 | 0.7000 | 12,337.2647 | ||||||
Residential type | 12 | 441.0704 | 1 | 3319.6948 | 1264.1240 | 9514.3681 | 49.1827 | 1147.4072 | 38.5781 |
60 | 419.9252 | 1 | 3160.5468 | ||||||
64 | 403.1284 | 1 | 3034.1265 | ||||||
17 | 234.3979 | 0.7000 | 2214.4776 | - | 14,374.1623 | ||||
49 | 544.6564 | 0.8115 | 5145.6495 | ||||||
61 | 742.4211 | 0.7000 | 7014.0352 | ||||||
Industrial type | 11 | 384.3114 | 1 | 2892.5010 | 928.1752 | 6985.8657 | 44.2924 | 1279.5147 | 32.3084 |
60 | 251.6425 | 1 | 1893.9754 | ||||||
64 | 292.2213 | 1 | 2199.3893 | ||||||
17 | 268.1524 | 0.7373 | 2533.3738 | - | 15,287.0024 | ||||
49 | 537.8695 | 0.8126 | 5081.5304 | ||||||
61 | 812.0757 | 0.7000 | 7672.0982 | ||||||