Table 6 Prony coefficients obtained from the generalized Maxwell model.
T (℃) | RH (%) | Prony series | gi | ki | τi | R2 |
|---|---|---|---|---|---|---|
− 25 | 0 | 1 | 0.09987 | 0.09987 | 3.5589 | 0.998 |
2 | 0.29489 | 0.29489 | 35.486 | |||
3 | 0.26224 | 0.26224 | 281.15 | |||
25 | 0 | 1 | 0.10254 | 0.10254 | 12.958 | 0.998 |
2 | 0.56938 | 0.56938 | 0.78209 | |||
3 | 0.06598 | 0.06598 | 79.927 | |||
55 | 0 | 1 | 0.02705 | 0.02705 | 855.47 | 0.998 |
2 | 0.02987 | 0.02987 | 58.877 | |||
3 | 0.80424 | 0.80424 | 3.742 | |||
55 | 90 | 1 | 0.03574 | 0.03574 | 42.695 | 0.995 |
2 | 3.2E-07 | 3.2E-07 | 0.61861 | |||
3 | 0.8509 | 0.8509 | 0.33983 | |||
85 | 0 | 1 | 0.05220 | 0.05220 | 1821.2 | 0.995 |
2 | 0.03002 | 0.03002 | 51.686 | |||
3 | 0.80997 | 0.80997 | 0.51948 |