Table 4 Results of FEM.
From: Experimental and numerical investigations on the bending capacity of cold-formed steel box headers
Specimen | RFEM | RFEM/REXP | |
|---|---|---|---|
No | Designation | (kN) | Â |
S01 | 92 × 92-1/1-0-G1 | 15.82 | 1.025 |
S02 | 92 × 92-1/1-0-G2 | 17.04 | 1.068 |
S03 | 92 × 92-1/2-0-G1 | 21.8 | 1.187 |
S04 | 92 × 92-1/2-0-G2 | 23.48 | 1.213 |
S05 | 92 × 92-2/1-0-G1 | 25.36 | 0.961 |
S06 | 92 × 92-2/2-0-G1 | 32.68 | 1.046 |
S07 | 200 × 92-1/2-0-G1 | 41.32 | 1.120 |
S08 | 200 × 92-1/2-0-G3 | 44.26 | 1.028 |
S09 | 200 × 92-2/1-0-G3 | 56.26 | 0.922 |
S10 | 200 × 92-2/2-0-G3 | 79.36 | 1.110 |
S11 | 150 × 150-1/1-60-G1 | 21.98 | 0.911 |
S12 | 92 × 150-1/1-60-G1 | 14.06 | 0.978 |
S13 | 92 × 150-2/1-60-G1 | 26.04 | 0.979 |
| Â | Average | Â | 1.042 |
| Â | Standard deviation | Â | 0.095 |