Table 10 Study of the change in the THD and amplitude value of the fundamental (50 Hz) for the both techniques.

From: Power regulation of variable speed multi rotor wind systems using fuzzy cascaded control

 

Techniques

DPC-PI strategy

CFPC-PWM technique

THD (%)

Test 1

0.28

0.21

Test 2

0.53

0.37

Test 2—Test 1

0.25

0.16

Ratios

47.16%

43.24%

Amplitude value of the fundamental (50 Hz)

Test 1

389.50 A

389.80 A

Test 2

404 A

405 A

Test 2—Test 1

14.50 A

15.20 A

Ratios

3.58%

3.75%