Table 3 Mechanical power of both WTs.
From: Power regulation of variable speed multi rotor wind systems using fuzzy cascaded control
Times (s) | Mechanical power (MW) | Ratios (%) | Average ratio(%) | |
|---|---|---|---|---|
SRWT | MRWT | |||
1 | 0.49 | 1.31 | 62.59 | 63.14 |
2 | 0.647 | 1.29 | 49.84 | |
3 | 0.62 | 1.06 | 51.50 | |
4 | 0.49 | 1.32 | 62.87 | |
5 | 0.49 | 1.32 | 62.87 | |
6 | 0.51 | 1.33 | 61.65 | |
7 | 0.31 | 1.14 | 72.80 | |
8 | 0.24 | 1.03 | 76.69 | |
9 | 0.24 | 1.02 | 76.47 | |
10 | 0.65 | 1.42 | 54.22 | |