Table 4 Comparison of calculation results for different sample sizes.
From: Research on methods for controlling strand sag in main cables
f0 (m) | \(\delta\) (× 100%) | f0 (m) | \(\delta\) (× 100%) | |||||
|---|---|---|---|---|---|---|---|---|
\(\mu_{{f_{0} }}\) | \(\sigma_{{f_{0} }}\) | \(\mu_{\delta }\) | \(\sigma_{\delta }\) | \(\mu_{{f_{0} }}\) | \(\sigma_{{f_{0} }}\) | \(\mu_{\delta }\) | \(\sigma_{\delta }\) | |
Method I (d = 0 cm) | Method II (d = 10 cm) | |||||||
N = 200 | 83.258 | 0.0065 | 6.18 | 0.67 | 83.158 | 0.0067 | 6.25 | 0.71 |
N = 300 | 83.258 | 0.0066 | 6.20 | 0.69 | 83.158 | 0.0066 | 6.22 | 0.70 |
Method III (d = 10 cm) | Method IV (d = 1 cm) | |||||||
N = 200 | 83.158 | 0.0066 | 12.85 | 0.50 | 83.128 | 0.0085 | 26.23 | 1.25 |
N = 300 | 83.158 | 0.0066 | 12.88 | 0.48 | 83.128 | 0.0083 | 26.25 | 1.28 |