Table 1 Infinite variance process parameters of the fault signals.

From: Robust post-processing time frequency technology and its application to mechanical fault diagnosis

Fault type

Measurement point

Infinite variance process parameters

\(\alpha\)

\(\beta\)

\(\gamma\)

\(\mu\)

No fault

DE

2.0

 − 1

0.0452

0.0136

FE

2.0

0.9365

0.0485

0.031

Inner race fault

DE

1.8883

 − 0.1190

0.4030

0.0061

FE

1.7119

0.1119

0.1241

0.0318

Ball fault

DE

2.0

0.3951

0.1208

0.0086

FE

2.0

0.3957

0.0587

0.0296

Fault position

Centered at 6:00

DE

1.1559

 − 0.0162

0.1393

0.0110

FE

1.4784

 − 0.0497

0.0905

0.0289

Orthogonal at 3:00

DE

1.4039

0.0784

0.3544

0.0353

FE

1.5435

0.0354

0.1256

0.0361

Opposite at 12:00

DE

1.1584

 − 0.0149

0.1256

0.0167

FE

1.6424

 − 0.0526

0.0732

0.0308