Table 5 Heat balance temperature of each temperature measurement point.
From: Experimental study of dual-cycle thermal management system for engineering radiator
Temperature measurement point | Temperature (°C) | |
|---|---|---|
Traditional cooling system | Dual-cycle cooling system | |
Inlet of engine coolant | 84 | 83 |
outlet of engine coolant | 81 | 78 |
Inlet of hydraulic oil | 71 | 69 |
Outlet of hydraulic oil | 65 | 51 |
Inlet of transmission oil | 92 | 72 |
Outlet of transmission oil | 82 | 65 |