Table 2 Data of renewable sources and hydrogen storage.

From: Stochastic economic sizing and placement of renewable integrated energy system with combined hydrogen and power technology in the active distribution network

WF data2

\(\:{\stackrel{-}{P}}^{BS}\) (kW)

50

Maximum number of WSs

5

Max of GBS (m3)

43,900

ICWS ($/year)

8000

Hydrogen storage data19

MCWS ($/year)

250

Maximum number of P2Hs

10

\(\:{\stackrel{-}{P}}^{WS}\) (kW)

50

ICP2H ($/year)

7000

vC−IN, vC−OUT, vR (m/s)

2.5, 13, 10

MCP2H ($/year)

50

Max of vWS (m/s)

9.8

\(\:{\stackrel{-}{P}}^{P2H}\) (kW)

50

PVF data26

ηP2H (%)

75

Maximum number of PVs

100

Maximum number of H2Ps

10

ICPV ($/year)

525

ICH2P ($/year)

3200

MCPV ($/year)

0

MCH2P ($/year)

25

\(\:{\stackrel{-}{P}}^{PV}\) (kW)

1.5

\(\:{\stackrel{-}{P}}^{H2P}\) (kW)

20

Max of IPV (kW/m2)

0.82

ηH2P (%)

51

BUF data2

Maximum number of HTs

10

Maximum number of BSs

5

ICHT ($/year)

10,000

ICBS ($/year)

16,000

MCHT ($/year)

100

MCBS ($/year)

300

\(\:{\widehat{E}}^{HT},\:{\underset{\_}{E}}^{HT},\:{\stackrel{-}{E}}^{HT}\) (kWh)

20, 20, 200