Table 2 Data of renewable sources and hydrogen storage.
WF data2 | \(\:{\stackrel{-}{P}}^{BS}\) (kW) | 50 | ||
|---|---|---|---|---|
Maximum number of WSs | 5 | Max of GBS (m3) | 43,900 | |
ICWS ($/year) | 8000 | Hydrogen storage data19 | ||
MCWS ($/year) | 250 | Maximum number of P2Hs | 10 | |
\(\:{\stackrel{-}{P}}^{WS}\) (kW) | 50 | ICP2H ($/year) | 7000 | |
vC−IN, vC−OUT, vR (m/s) | 2.5, 13, 10 | MCP2H ($/year) | 50 | |
Max of vWS (m/s) | 9.8 | \(\:{\stackrel{-}{P}}^{P2H}\) (kW) | 50 | |
PVF data26 | ηP2H (%) | 75 | ||
Maximum number of PVs | 100 | Maximum number of H2Ps | 10 | |
ICPV ($/year) | 525 | ICH2P ($/year) | 3200 | |
MCPV ($/year) | 0 | MCH2P ($/year) | 25 | |
\(\:{\stackrel{-}{P}}^{PV}\) (kW) | 1.5 | \(\:{\stackrel{-}{P}}^{H2P}\) (kW) | 20 | |
Max of IPV (kW/m2) | 0.82 | ηH2P (%) | 51 | |
BUF data2 | Maximum number of HTs | 10 | ||
Maximum number of BSs | 5 | ICHT ($/year) | 10,000 | |
ICBS ($/year) | 16,000 | MCHT ($/year) | 100 | |
MCBS ($/year) | 300 | \(\:{\widehat{E}}^{HT},\:{\underset{\_}{E}}^{HT},\:{\stackrel{-}{E}}^{HT}\) (kWh) | 20, 20, 200 | |