Table 2 Factors used in the calculation of UV fluences for 255, 267, and 279 nm UV LEDs, UV fluences, and Exposure Times Associated with UV fluences.
From: UV LED disinfection as a novel treatment for common salmonid pathogens
Wavelength | |||
|---|---|---|---|
255 nm | 267 nm | 279 nm | |
Petri Factor | 0.891 | 0.857 | 0.846 |
Incident Irradiance (mW/cm2) | 0.088 | 0.404 | 0.511 |
UV Fluences (mJ/cm2) | 1–10 | 1–10 | 1–10 |
Exposure Times (Pure Water; min) | 0.13–2.3 | 0.03–0.53 | 0.02–0.42 |
Exposure Times (Wastewater; min) | 0.37–3.75 | 0.08–0.85 | 0.07–0.63 |