Table 4 Variation in permeability by location.
Various locations | Heating days(d) | Permeability(m2) |
|---|---|---|
Probe A (4.5, 8.6) | 0 | 2.67 × 10–17 |
100 | 1.0911 × 10–16 | |
200 | 1.9136 × 10–16 | |
300 | 3.0346 × 10–16 | |
400 | 2.2437 × 10–11 | |
500 | 2.3695 × 10–11 | |
Probe B (5.5, 7.8) | 0 | 2.67 × 10–17 |
100 | 6.4844 × 10–17 | |
200 | 1.2125 × 10–16 | |
300 | 2.0211 × 10–16 | |
400 | 1.8 × 10–14 | |
500 | 1.9822 × 10–11 | |
Probe C (6.5, 7.1) | 0 | 2.67 × 10–17 |
100 | 4.9883 × 10–17 | |
200 | 9.5692 × 10–17 | |
300 | 1.6415 × 10–16 | |
400 | 1.6529 × 10–14 | |
500 | 1.8516 × 10–14 | |
Probe D (7.5, 6.3) | 0 | 2.67 × 10–17 |
100 | 4.4755 × 10–17 | |
200 | 8.6407 × 10–17 | |
300 | 1.5011 × 10–16 | |
400 | 1.5961 × 10–14 | |
500 | 1.8008 × 10–14 |