Table 3 Results of tension clamp test results carried out under monotonic stress until fracture.

From: The influence of geometric nonconformance of the SB4 tension clamps on their strength and elasticity characteristics

N = 3

Fmax

FBreak

W Fmax

WBreak

tTest

dL (Fmax)

Unit

N

Nmm

s

mm

Good– C

\(\:\stackrel{-}{{x}}\)

203

198

4482.72

4642.12

29.73

36.6

\(\:{s}\)

17.8

17.8

688.67

692.12

1.46

2.6

\(\nu\)

8.77

8.98

15.36

14.91

4.9

7.04

Bad – INC

\(\:\stackrel{-}{{x}}\)

189

184

3983.43

4081.94

28.55

35

\(\:{s}\)

17.6

18.5

971.06

1047.23

3.33

5.2

\(\nu\)

9.3

10.08

24.38

25.66

11.65

14.87