Table 13 Variation of \(E_{HT}\), \(E_{MT}\), \(E_{MF}\), \(E_{FF}\), \(E_{T}\), and Be for different Da with \(\phi _{hnp}=0.04\), \(Ra=10^{5}\), \(Ha=25\), \(Le=5\), \(N=1\) and \(Rd=1\).

From: Thermosolutal convection in a baffled curvilinear porous cabinet filled with magneto radiative hybrid nanofluid

 

Da

\(E_{HT}\)

\(E_{MT}\)

\(E_{MF}\)

\(E_{FF}\)

\(E_{T}\)

Be

Case-1

\(10^{-4}\)

7.019

3.259

0.041

2.205

12.526

0.820

\(10^{-3}\)

7.243

6.727

1.670

18.643

34.284

0.407

\(10^{-2}\)

8.019

7.483

22.657

35.190

73.350

0.211

Case-2

\(10^{-4}\)

3.029

1.359

0.016

0.790

5.195

0.844

\(10^{-3}\)

3.065

2.167

0.956

7.016

13.205

0.396

\(10^{-2}\)

3.320

2.765

8.199

15.915

30.201

0.201

Case-3

\(10^{-4}\)

1.786

0.903

0.043

1.668

4.401

0.611

\(10^{-3}\)

1.863

2.438

2.243

11.632

18.179

0.236

\(10^{-2}\)

2.512

3.490

21.128

26.534

53.665

0.111