Table 3 Time delay and distance error over ten measurements using the synchronized oscillator.
From: Nonlinear electronic oscillators as time sensors for high-precision positioning applications
Statistic | Absolute Time Error (ps) | Absolute Distance Error (mm) | Relative Error |
|---|---|---|---|
Maximum Value | 1.12 | 0.33 | \(8 \times 10^{-6}\) |
Minimum Value | \(5 \times 10^{-6}\) | \(2 \times 10^{-6}\) | \(4 \times 10^{-11}\) |
Mean Value | 0.43 | 0.13 | \(3.1 \times 10^{-6}\) |
Std | 0.37 | 0.11 | \(2.7 \times 10^{-6}\) |