Sr No. | Details | Parameters | Values | Standard error |
|---|---|---|---|---|
1 | Depth of V-Cut | h | From 0.75 to 1.75 mm | - |
2 | Change in pressure | \(\Delta P\) | From 100 to 400 kPa | - |
3 | Cumulative Distribution Value | \(D{v_\% }\) | 10 to 90% | - |
4 | Constant | \(z0\) | 198.09299 | 29.2202 |
5 | Constant | a | -0.51027 | 0.14109 |
6 | Constant | b | 9.84897 | 0.7999 |
7 | Constant | c | 4.91864\(\times {10^{ - 4}}\) | 1.76803\(\times {10^{ - 4}}\) |
8 | Constant | d | -0.02689 | 0.0072 |
9 | Constant | f | -0.00503 | 9.78287\(\times {10^{ - 4}}\) |