Table 1 Orkiszewski method-based criteria for determining the flow regime.

From: Evaluating the temperature profile and pressure drops in gas-lift wells via coupled temperature–pressure analysis

No

Flow regime

Criteria

I

Bubble flow

\({{q_{{\text{g}}} } \mathord{\left/ {\vphantom {{q_{{\text{g}}} } {q_{{\text{t}}} }}} \right. \kern-0pt} {q_{{\text{t}}} }} < L_{{\text{B}}}\)

II

Slug flow

\({{q_{{\text{g}}} } \mathord{\left/ {\vphantom {{q_{{\text{g}}} } {q_{{\text{t}}} }}} \right. \kern-0pt} {q_{{\text{t}}} }} > L_{{\text{B}}} , \, \overline{v}_{g} < L_{{\text{S}}}\)

III

Transition flow

\(L_{{\text{S}}} < \overline{v}_{g} < L_{{\text{M}}}\)

IV

Annular-Mist flow

\(L_{{\text{M}}} < \overline{v}_{g}\)