Table 3 Repeated Tests - Statistical results of the deviation distance from the neutral position at different pressures, measured after the valve spool returns from the left position (L-Neu).
Value | 5Â MPa | 10Â MPa | 15Â MPa | 20Â MPa | 25Â MPa |
|---|---|---|---|---|---|
Average/mm | 0.38 | 0.81 | 1.54 | 2.64 | 2.68 |
Max/mm | 0.42 | 0.85 | 1.56 | 2.68 | 2.72 |
Min/mm | 0.33 | 0.77 | 1.49 | 2.59 | 2.64 |