Table 4 Total heat flux rates.

From: Study on the battery thermal management system for cylindrical lithium-ion battery with nano-doped phase change material and liquid cooling

Description

PCM

5%

10%

15%

Total heat flux (W/m2)

1037

2073.9

3214.6

4147.8

X-heat flux (W/m2)

830.6

1661.2

2574.9

3322.4

Y-heat flux (W/m2)

264.4

528.8

819.63

1057.6

Z-heat flux (W/m2)

983.19

1966.4

3047.9

3932.7