Table 15 Different optimization options for renewable energy systems with fuel cell storage.
From: Economic and environmental assessment of different energy storage methods for hybrid energy systems
Results | 1 | 2 | 3 | 4 |
|---|---|---|---|---|
NPC ($) | 4.80 M | 5.96 M | 6.24 M | 6.53 M |
LCOE ($) | 3.85 | 4.82 | 4.75 | 4.98 |
FC (kW) | 250 | 250 | – | 250 |
PV (kW) | 101 | 214 | 145 | 148 |
WT(n) | 31 | – | 66 | 76 |
BioGen(kW) | – | – | 15 | 15 |
Electrolyzer(kW) | 50 | 50 | 50 | 50 |
Refomer(kW) | 100 | 100 | 100 | 100 |
HTank(kg) | 100 | 100 | 50 | 50 |
Converter(kW) | 5.38 | 10.6 | 50.3 | 50.5 |
Dispatch | CC | CC | CC | CC |