Table 12 Energy analysis of simultaneous recuperator cycle with ORC.
Component | Fluid | (R-123) | (R-245FA) | (R-600) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Heat transfer or work | Energy efficiency | Heat Transfer or Work | Energy efficiency | Heat Transfer or Work | Energy efficiency | ||||||
Hot | Cold | (kw) | Cycles | Total | (kw) | Cycles | Total | (kw) | Cycles | Total | |
sCO2 Turbine | sCO2 | sCO2 | 11,737 | 41.29% | 25.51% | 11,737 | 39.32% | 25.02% | 11,737 | 37.95% | 24.63% |
sCO2 Pump | sCO2 | sCO2 | 2410 | 2410 | 2410 | ||||||
sCO2 Recuperator | sCO2 | Air | 26,141 | 26,141 | 26,141 | ||||||
sCO2 Condenser | sCO2 | sCO2 | 17,135 | 17,135 | 17,135 | ||||||
sCO2 HRSG | Smoke | sCO2 | 26,463 | 26,463 | 26,463 | ||||||
ORC Turbine | ORC | ORC | 1614 | 11.17% | 1089 | 7.53% | 724.1 | 4.99% | |||
ORC Pump | ORC | ORC | 15.98 | 12.34 | 10.14 | ||||||
ORC Condenser | ORC | Air | 12,707 | 13,227 | 13,590 | ||||||
ORC HRSG | Smoke | ORC | 14,304 | 14,304 | 14,304 | ||||||