Table 2 Quantitative results on the HECKTOR 2021 dataset over 5-fold validation for 0, 1, 5, and 10 number of clicks and for the overall averaged.
From: Interactive 3D segmentation for primary gross tumor volume in oropharyngeal cancer
Model | 0 Clicks | 1 Click | 5 Clicks | 10 Clicks | 0 to 10 Avg. |
|---|---|---|---|---|---|
(a) Dice similarity coefficient performance | |||||
2S-ICR (ours) | 0.752 ± 0.203 | 0.787 ± 0.191 | 0.850 ± 0.101 | 0.870 ± 0.067 | 0.836 ± 0.131 |
0.663 ± 0.316 | 0.755 ± 0.211 | 0.840 ± 0.096 | 0.861 ± 0.065 | 0.817 ± 0.157 | |
DeepEdit-2513 | 0.729 ± 0.243 | 0.767 ± 0.197 | 0.828 ± 0.110 | 0.851 ± 0.076 | 0.814 ± 0.144 |
DeepEdit-5013 | 0.738 ± 0.229 | 0.765 ± 0.200 | 0.822 ± 0.128 | 0.847 ± 0.094 | 0.812 ± 0.150 |
(b) HD95 performance | |||||
2S-ICR (ours) | 3.000 ± 4.103 | 2.236 ± 2.123 | 2.000 ± 1.414 | 1.732 ± 0.822 | 2.000 ± 1.586 |
3.674 ± 9.273 | 3.000 ± 3.099 | 2.000 ± 1.268 | 2.000 ± 1.035 | 2.236 ± 1.430 | |
DeepEdit-2513 | 3.317 ± 6.690 | 3.000 ± 3.385 | 2.236 ± 1.430 | 2.000 ± 1.414 | 2.236 ± 1.874 |
DeepEdit-5013 | 3.081 ± 5.413 | 3.000 ± 3.385 | 2.236 ± 1.430 | 2.000 ± 1.414 | 2.236 ± 1.585 |