Table 6 Statistical table of seepage area ratio for inclined cracks.
From: Experimental study on seepage characteristics model of tunnel lining based on infrared imaging
Condition | Lining position | Flow rate (mL/min) | Seepage area ratio (%) |
|---|---|---|---|
1 | Vault | 300 | 17.39 |
2 | 600 | 20.47 | |
3 | 900 | 21.00 | |
4 | 1200 | 19.25 | |
5 | Spandrel | 300 | 27.11 |
6 | 600 | 30.18 | |
7 | 900 | 41.18 | |
8 | 1200 | 59.30 | |
9 | Haunch | 300 | 21.20 |
10 | 600 | 23.28 | |
11 | 900 | 28.43 | |
12 | 1200 | 31.38 |