Table 2 Effect of applied voltage.
From: Improving electrocoagulation performance by adding environmentally friendly materials
Voltage (V) | Volume (L) | Removal efficiency (%) | |||
|---|---|---|---|---|---|
TDS | TSS | Color | COD | ||
6 | 1L | 14 ± 1.22 | 84 ± 0.81 | 36 ± 1.51 | 65 ± 1.01 |
3L | 12 ± 1.02 | 80 ± 0.72 | 33 ± 1.22 | 60 ± 0.92 | |
5L | 10 ± 0.81 | 75 ± 0.64 | 30 ± 1.02 | 55 ± 0.80 | |
12 | 1L | 28 ± 1.52 | 88 ± 0.92 | 67 ± 1.81 | 72.5 ± 1.20 |
3L | 25 ± 1.33 | 85 ± 0.80 | 63 ± 1.54 | 68 ± 1.12 | |
5L | 23 ± 1.10 | 80 ± 0.71 | 60 ± 1.32 | 65 ± 1.01 | |
18 | 1L | 38 ± 1.82 | 92 ± 1.03 | 72 ± 2.02 | 85.9 ± 1.51 |
3L | 35 ± 1.63 | 90 ± 0.91 | 70 ± 1.81 | 82 ± 1.32 | |
5L | 32 ± 1.41 | 88 ± 0.82 | 68 ± 1.61 | 80 ± 1.24 | |
24 | 1L | 48 ± 2.01 | 93.6 ± 1.14 | 78 ± 2.20 | 86 ± 1.61 |
3L | 45 ± 1.93 | 92 ± 1.03 | 75 ± 2.00 | 84 ± 1.52 | |
5L | 42 ± 1.72 | 90 ± 0.90 | 73 ± 1.90 | 82 ± 1.41 | |