Table 9 Constants in the PFO model for COD removal for 1L, 3L, and 5L.
From: Improving electrocoagulation performance by adding environmentally friendly materials
Volume (L) | Parameters | |||||
|---|---|---|---|---|---|---|
R2 | Slop | Intercept | K1 | Experimental qe (mg/L) | Calculated qe (mg/L) | |
1L | 0.9999 |  − 0.0054 |  − 0.6741 | 0.0124 | 1.8155 | 0.2118 |
3L | 0.9998 |  − 0.0050 |  − 0.7000 | 0.0118 | 1.700 | 0.200 |
5L | 0.9997 |  − 0.0048 |  − 0.7200 | 0.0115 | 1.600 | 0.195 |