Table 3 Calculation results of evaporator tubes for each program.

From: Research on the heat transfer characteristics of evaporator tubes in micro turbine engines based on biomimetic parallel leaf vein structure

Programmatic

Evaporation rate(%)

Outlet SMD

(μm)

Air flow

(g/s)

Average outlet temperature(K)

a

18.01

45.46

2.554

532.47

b

3.01

36.51

2.552

530.43

c

3.92

30.94

2.556

530.11

d

6.79

38.86

2.554

530.59

e

2.37

35.39

2.554

531.21

f

2.50

40.69

2.555

528.98

g

23.98

29.52

2.551

539.93

h

2.58

33.66

2.555

529.19

i

5.20

39.81

2.552

534.64