Table 3 Results of mesh quality test.

From: Laser irradiation of human skin tissue after gold nanoparticles injection for thermal ablation processes – a combined experimental and numerical approach

 

Mesh density

Low

Medium

High

Element size

0.3 mm

0.2 mm

0.1 mm

Number of nodes

286,889

1,480,656

5,112,377

Number of elements

459,539

2,158,913

8,288,187

Average skewness

0.213

0.194

0.187

Average element quality

0.726

0.711

0.698

Average aspect ratio

2.425

2.373

2.507

Average orthogonal quality

0.839

0.865

0.864