Table 3 Comparison with other EO based disinfection studies.
Matrix/Target Organisms &Genes | Current Density/ Electrode | % Inactivation | Key notes | References |
|---|---|---|---|---|
Hospital urine; Klebsiella (blaKPC), Pseudomonas (blaOXA-50), Staph (mecA) | 50 A/m², MMO anode, w/wo UV | 84.9 | UV combined with EO boosts ARG reduction and speed of disinfection. | |
Hospital wastewater; six bacteria w/ NDM-1, mcr-1, tetX | 3 V; varied time | 90 | Up to 90% ARG removal reported. | |
Penicillin G in synthetic urine | MMO-Ti/RuO₂ IrO₂, EC, 1.6 Ah/dm³ | 55% TOC, 76% COD | Synergistic photo-electrolysis higher; MMO alone < 90% TOC removal | |
Escherichia coli, Bacillus subtilis, Staphylococcus aureus, Salmonella enterica, Acinetobacter calcoacetius, Serratia marcescens, Listeria sp., Enterococcus faecalis in simulated wastewater | MMO anodes, 7.14 mA/cm2 at 9 min | 96 | Effective disinfection at low current density within less time and at a lower cost, 0.18$/m3. | Present study |