Table 3 Energy consumption required for COD removal per I L with cost.
Energy | Energy (KWh/KgCOD) | Cost for 1 L Treatment | ||||
|---|---|---|---|---|---|---|
UV/H2O2 | Photo Fenton | photo Fenton like | UV/H2O2 | Photo Fenton | photo Fenton like | |
UV | 16.82 | 4.26 | 8.82 | 0.082418 | 0.020874 | 0.043218 |
Stirrer | 13.57 | 3.40 | 6.84 | 0.066493 | 0.01666 | 0.033516 |
Total cost of Energy USD/L | 0.148911 | 0.037534 | 0.076734 | |||