Table 2 Mix proportion design and basic mechanical indicators of glass sand concrete.
Sample | Cement | River sand | Glass sand | Crushed stone | Water | fcu/MPa | fck/MPa | Ec/GPa | εck |
|---|---|---|---|---|---|---|---|---|---|
kg/m3 | |||||||||
C30 | 440 | 611.00 | 0.00 | 1134 | 215 | 32.13 | 19.99 | 27.40 | 0.00208 |
GSC-5 | 440 | 580.45 | 30.55 | 1134 | 215 | 33.24 | 22.03 | 27.53 | 0.00238 |
GSC-15 | 440 | 519.35 | 91.65 | 1134 | 215 | 34.81 | 25.29 | 28.96 | 0.00229 |
GSC-30 | 440 | 427.70 | 183.30 | 1134 | 215 | 30.24 | 19.28 | 28.99 | 0.00207 |
GSC-60 | 440 | 244.40 | 366.60 | 1134 | 215 | 26.05 | 17.58 | 27.51 | 0.00195 |