Table 1 Formulas for calculating radiological protection factors.
Indicator/parameter | Formula | Numbering | Bibliography |
|---|---|---|---|
Radium equivalent activity | \(\:{Ra}_{eq}={A}_{Ra}+{1.43A}_{Th}+{0.077A}_{K}\) | (1) | |
Outdoor external dose | \(\:{D}_{out}=0.462{A}_{Ra}+0.604{A}_{Th}+0.0417{A}_{K}\) | (2) | |
Indoor external dose | \(\:{D}_{in}=0.92{A}_{Ra}+1.1{A}_{Th}+0.080{A}_{K}\) | (3) | |
Annual effective dose equivalent outdoors | \(\:{E}_{out}={D}_{out}\cdot\:8766\cdot\:0.8\cdot\:0.7\cdot\:{10}^{-6}\) | (4) | |
Annual effective dose equivalent indoors | \(\:{E}_{in}={D}_{in}\cdot\:8766\cdot\:0.2\cdot\:0.7\cdot\:{10}^{-6}\) | (5) | |
Total annual effective dose equivalent | \(\:{E}_{tot}={E}_{out}+{E}_{in}\) | (6) |