Table 8 The average results of splitting tensile strength for the S mixture at room temperature (RT) and after furnace and water cooling.
Mixture | Splitting tensile strength after furnace cooling (MPa) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
RT | 200 °C | 400 °C | 600 °C | ||||||||
7 | 28 | 10 | 20 | 30 | 10 | 20 | 30 | 10 | 20 | 30 | |
S | 1.65 (0.092) * | 2.02 (0.074) * | 2.15 (0.078) * | 2.27 (0.0.076) * | 2.36 (0.068) * | 1.66 (0.107) * | 1.31 (0.153) * | 0.57 (0.175) * | 0.62 (0.177) * | 0.52 (0.188) * | 0.31 (0.209) * |
Splitting strength after water cooling (MPa) | |||||||||||
2.07 (0.074) | 2.18 (0.080) | 2.28 (0.088) | 1.40 (0.129) | 0.67 (0.147) | 0.36 (0.275) | 0.41 (0.212) | 0.31 (0.248) | 0.26 (0.232) | |||