Table 6 Kinetic parameters calculated for the removal of Cd2+ ions by CuS nanorods.
Model | Parameters | Values | ||
|---|---|---|---|---|
303 K | 313 K | 323 K | ||
Pseudo first order | k1 (min− 1) | 0.0314 | 0.0387 | 0.0452 |
qe (mg g− 1) | 83.12 | 82.45 | 81.68 | |
R2 | 0.984 | 0.981 | 0.978 | |
Pseudo second order | k2 (min− 1) | 0.0005 | 0.0006 | 0.0008 |
qe (mg g− 1) | 84.25 | 83.61 | 82.93 | |
R2 | 0.998 | 0.997 | 0.996 | |
Intraparticle diffusion | kit (mg gmin0.5) | 5.12 | 5.87 | 6.45 |
C (mg g− 1) | 45.21 | 43.78 | 42.15 | |
R2 | 0.962 | 0.958 | 0.953 | |
Elovich | α | 0.063 | 0.051 | 0.042 |
β | 0.072 | 0.079 | 0.085 | |
R2 | 0.972 | 0.968 | 0.963 | |