Table 15 NT-based concrete’s chloride ion penetrability test result.

From: Mechanical, microstructure, durability, and economic assessment of nano titanium dioxide integrated concrete

Cube designation

RCPT Coulombs

(Q)

Chloride ion penetrability

Chloride ion penetrability

(According to ASTM C1202) (Q) 47

0NT

2632 ± 105

Moderate

High: >4000

Moderate: 2000–4000

Low: 1000–2000

Very Low: 100–1000

Negligible: < 100

0.5NT

2759 ± 112

Moderate

1NT

3200 ± 128

Moderate

1.5NT

3540 ± 135

Moderate