Table 13 Energy consumption accounting of hollow fiber nanofitration.

From: Pilot-scale research on advanced treatment of surface water from Beijing-Hangzhou grand Canal with seasonably variable temperature based on Hollow fiber nanofiltration

Electric device

Installed power (kW)

Daily energy consumption (kWh/d)

Daily output of permeat (t/d)

Electricity charge (RMB/KWh)

Energy consumption per ton of permeat (RMB/t)

Supply Pump

1.5

6.9238

25

0.63

0.17448

Circulating Pump

2.2

11.9361

25

0.63

0.30079

Flush Pump

1.5

0.3456

25

0.63

0.00871

Dosing Pump of NaClO

0.024

0.0004

25

0.63

0.00001

Dosing Pump of NaOH

0.024

0.0004

25

0.63

0.00001

Dosing Pump of Citric Acid

0.024

0.0004

25

0.63

0.00001

Other Low-Power Devices

0.03

0.7321

25

0.63

0.01845

In Total

0.50246

  1. Bold value indicates statistically significant.