Table 4 Designed operating parameters of pilot equipment.

From: Pilot-scale research on advanced treatment of surface water from Beijing-Hangzhou grand Canal with seasonably variable temperature based on Hollow fiber nanofiltration

Parameter

Unit

Value range

Influent pressure

bar

2.5 ~ 5.5

Frequency of hydraulic cleaning

once per 1-h

Intensity of hydraulic cleaning

Forward Flush: 4 m3/h, Backwash: 20 LMH (5 bar), Air Scouring: 7.5 Nm3/h

Duration of hydraulic cleaning

min

1

Frequency of chemically enhanced backwash (CEB)

once per 48-h

Dosage of CEB agents

mg/L

NaClO:200, NaOH:250, Citric Acid:4000

Duration of CEB with alkaline agents

min

20 (2.5 for dosing, 15 for soaking with recirculation, 2.5 for rinsing)

Duration of CEB with acid agent

min

20 (2.5 for dosing, 15 for soaking with recirculation, 2.5 for rinsing)

Frequency of cleaning in place (CIP)

0