Table 7 Test results of magnetized water in composite time-varying magnetic field.
Current and frequency | pH | Conductivity C/cm | Surface tension N/m | Viscosity mPa s | ||||
|---|---|---|---|---|---|---|---|---|
Orientation | P | S | P | S | P | S | P | S |
DC-SAC1 kHz | 7.83 | 7.88 | 150.5 | 165.7 | 65.8 | 65.9 | 1.54 | 1.55 |
DC-SAC3 kHz | 7.66 | 7.9 | 148.3 | 164.7 | 65.4 | 65 | 1.46 | 1.63 |
DC-SAC5 kHz | 7.99 | 8.06 | 148.1 | 164.6 | 64.2 | 63.9 | 1.54 | 1.59 |
DC-SAC8 kHz | 8.11 | 8.1 | 149.1 | 166.4 | 62 | 62.3 | 1.52 | 1.54 |
DC-TAC1 kHz | 7.71 | 8.13 | 149.1 | 164.1 | 66.7 | 65.1 | 1.44 | 1.46 |
DC-TAC3 kHz | 7.94 | 8.25 | 149.6 | 165.4 | 66.5 | 65.6 | 1.46 | 1.57 |
DC-TAC5 kHz | 8.14 | 8.42 | 146.9 | 167.1 | 66.8 | 64.5 | 1.55 | 1.68 |
DC-TAC8 kHz | 8.08 | 8.51 | 147.7 | 168.7 | 64 | 63.3 | 1.37 | 1.75 |
DC-RAC1 kHz | 8.01 | 8.29 | 149.1 | 166.1 | 66 | 65.1 | 1.51 | 1.6 |
DC-RAC3 kHz | 8.15 | 8.35 | 148.2 | 168.4 | 63.4 | 64.6 | 1.46 | 1.71 |
DC-RAC5 kHz | 8.14 | 8.47 | 150.8 | 171.6 | 64.3 | 62.7 | 1.45 | 1.79 |