Table 1 Data of the fluid and the experimental setup.

From: Advanced optical measurement techniques for simultaneous fibre orientation and flow analysis complemented by machine learning

Fluid and components

Symbol

Value

Unit

Viscosity of Silicon oil

\(\eta _S\)

10,000

\(\frac{\text {mm}^2}{\text {s}}\)

Particle diameter

\(d_P\)

0.035

mm

Emitted light of Particles

\(\lambda _P\)

584

nm

Concentration Particles

\(c_P\)

0.057

\(\frac{\text {g}}{\text {L}}\)

Resolution

R

6.9

\(\frac{\text {pixel}}{\text {mm}}\)

Fibre length

\(l_F\)

30

mm

Fibre diameter

\(d_F\)

0.16

mm

Single fibre mass

\(m_F\)

0.8

\(10^{-3}\)g

Fibre volume fraction

\(\phi\)

\(5.9\times 10^{-3}\)

vol.-%

Specifications of the experiment

Symbol

Value

Unit

Angular velocity

\(\omega\)

0.1

\(\frac{\text {1}}{\text {s}}\)

Diameter outer cylinder

D

240

mm

Diameter interfering body

\(d_B\)

40

mm

Wavelength of laser

\(\lambda\)

532

nm