Table 2 Comparisons and summary statistics of fracture resistance (N) with different variables.

From: Fractographic analysis of 3D printed hybrid ceramic single crowns with different aging and post-curing times: an in-vitro study

Aging cycles

Fracture resistance (N) (mean ± SD)

p-value

10 min

20 min

5,000

536.00 ± 58.73

490.00 ± 77.57

0.110ns

10,000

481.67 ± 47.26

495.45 ± 77.89

0.625ns

p-value

0.065ns

0.843ns