Table 10 ANOVA analysis values determined by Box-Behnken design for influential variables in Cu2+ ion removal.

From: Synthesis, application and modelling of spherical magnetic silicon poly-N,N′-methylenebisacrylamide nanocomposite for effective copper removal from water

Source

Sum of squares

df

Mean square

F-value

p-value

 

Model

4896.82

9

544.09

1023.71

< 0.0001

Significant

A-NSM dose

1151.28

1

1151.28

2166.14

< 0.0001

 

B-Time

47.24

1

47.24

88.88

< 0.0001

 

C-Cu dose

2378.78

1

2378.78

4475.68

< 0.0001

 

AB

4.58

1

4.58

8.62

0.0219

 

AC

456.46

1

456.46

858.84

< 0.0001

 

BC

1.02

1

1.02

1.92

0.2085

 

A2

157.51

1

157.51

296.36

< 0.0001

 

B2

296.30

1

296.30

557.49

< 0.0001

 

C2

315.86

1

315.86

594.30

< 0.0001

 

Residual

3.72

7

0.5315

   

Lack of fit

3.72

3

1.24

   

Pure error

0.0000

4

0.0000

   

Cor total

4900.54

16

    

Std. Dev.

0.7290

R2

0.9992

   

Mean

82.60

Adjusted R2

0.9983

   

C.V. %

0.8826

Predicted R²

0.9879

   

Adeq precision

104.5887