Table 2 Simulation input parameters and assumptions.

From: Electrical energy reduction based on residential densification for passive heating and cooling load reduction in Jordan

Input data

Value

Family size

6 members

Metabolic rate

0.8 met

Summer clothing

0.5 clo

Occupancy time

All day

Air exchange

2 ach -1

Heat gain

80 W/person

Lighting

5 W/m2