Table 1 The performance of the tested PEMFC at 100% anode RH, 0.2 NLPM anode and cathode gas flow rate, and different temperatures and RH, using air and oxygen.

From: Integrated laboratory workflow for proton exchange membrane fuel cell fabrication and testing

 

Cathode RH (%)

Max Power (watt)

Voltage at Max Power (Volt)

Current at Max Power (Ampere)

Max Current can be reached (Ampere)

60 \(\rm ^\circ C\)

Air

50

0.704

0.354

2.044

3

60

0.721

0.373

1.829

2.5

70

0.605

0.305

1.854

3

80

0.718

0.374

1.826

2.5

90

0.699

0.413

1.708

2.5

100

0.745

0.407

1.982

2.5

Oxygen

50

1.638

0.442

4.087

5.5

60

1.794

0.413

4.500

6.5

70

1.272

0.452

2.783

3.5

80

1.841

0.413

4.203

5.5

90

1.816

0.422

4.323

5.5

100

1.444

0.500

2.822

3.5

70 \(\rm ^\circ C\)

Air

50

0.708

0.368

1.846

3

60

0.796

0.373

2.030

3

70

0.798

0.344

2.139

3

80

0.660

0.349

1.861

2.5

90

0.798

0.427

2.000

2.5

100

0.811

0.432

1.869

3

Oxygen

50

2.198

0.388

5.783

7.5

60

2.260

0.337

6.486

8.5

70

2.205

0.392

5.868

7.5

80

2.088

0.500

4.567

5.5

90

2.409

0.398

6.500

6.5

100

2.075

0.422

5.172

6.5