Table 4 Classification accuracy of the obtained results corresponds to the Ninapro DB2 dataset for varied motions (4–17) and channels (3–12).
Channels | Motions | |||
|---|---|---|---|---|
4 | 8 | 13 | 17 | |
3 | 90.27 ± 0.42 | 85.42 ± 0.33 | 79.71 ± 0.23 | 76.39 ± 0.26 |
5 | 95.44 ± 0.61 | 92.25 ± 0.37 | 89.29 ± 0.30 | 88.66 ± 0.23 |
8 | 96.62 ± 0.60 | 95.11 ± 0.42 | 93.00 ± 0.17 | 91.77 ± 1.58 |
12 | 98.13 ± 0.46 | 97.80 ± 0.176 | 96.53 ± 0.12 | 95.61 ± 0.06 |