Table 3 Experimental design using L9 orthogonal array.
Experiment No | Process parameters | ||
|---|---|---|---|
Waterjet pressure (P) MPa | Traverse speed (V) mm min− 1 | Standoff distance (SOD) mm | |
1 | 100 | 100 | 2 |
2 | 100 | 150 | 3 |
3 | 100 | 200 | 4 |
4 | 150 | 100 | 3 |
5 | 150 | 150 | 4 |
6 | 150 | 200 | 2 |
7 | 200 | 100 | 4 |
8 | 200 | 150 | 2 |
9 | 200 | 200 | 3 |