Table 3 Construction parameters of test DMP piles.

From: Innovative digital control minor-disturbance equipment for deep mixing

Items

Penetration

Repeating stirring

Withdraw

Phase

1–2

3–7

8

9–10

11–15

16

Depth range, m

0-4.6

4.6–16.8

16.8–18.0

14.0–18.0

4.6–14.0

0-4.6

Drilling rate, m/min

0.5

0.5

0.5

1.0

1.0

1.0

Rotating rate, r/min

25

25

25

30

30

30

Air pressure, kPa

≤ 300

≤ 300

≤ 300

≤ 300

≤ 300

≤ 300

Binder content, %

13

15

13

13

15

13

Water-binder ratio

1.5

1.5

1.5

1.0

1.0

1.0

Proportion of slurry, %

30

30

30

35

70

70

Slurry flow rate, L/min

27.7

31.9

27.7

54.3

108.5

94.1