Table 4 Statistical performance indicators of the slurry flow rate during different construction phases.

From: Innovative digital control minor-disturbance equipment for deep mixing

Phase

Set value (L/min)

Sample size

Mean (L/min)

SD (L/min)

CV (%)

Min (L/min)

Max (L/min)

1–2

27.7

115

27.69

0.74

2.7

25.8

29.4

3–7

31.9

356

31.89

0.53

1.7

29.1

33.2

8

27.7

24

27.55

0.62

2.3

26.7

29.4

9–10

54.3

151

54.36

0.72

1.3

52.2

56.2

11–15

108.5

233

108.33

1.31

1.2

96.5

109.8

16

94.1

113

94.15

0.70

0.7

92.6

97.3